Loading Rheostat 1.2KW Bank Manufacturer,Supplier and Exporter in India
Product Code : SCL-EAE-11312
The Loading Rheostat 1.2kW Bank has a stated loading capacity of 1.2 kW. It changes the effective resistance in a circuit so the operator can vary current and examine how an electrical source or machine behaves under different resistive-load conditions.
The unit is suitable for supervised bench experiments involving DC circuits, compatible electrical machines and power measurements. Its resistance range, rated voltage, maximum current, load-control method, element material, enclosure and cooling arrangement must be confirmed from the final technical quotation.
Key Features
1.2 kW load capacity: Provides resistive loading within the confirmed operating limits.
Adjustable resistance: Allows current and applied load to be varied during an experiment.
Electrical-load study: Supports observation of voltage drop, current flow and power dissipation.
Practical machine testing: Can be integrated with compatible motors, generators or training systems.
Accessible connections: Provides terminals for connection to laboratory circuits and meters.
Clear operating layout: Supports teacher demonstrations and supervised student practical work.
Reusable laboratory unit: Suitable for repeated operation within its rated duty cycle.
Technical Specifications
|
Specification |
Detail |
|
Product name |
Loading Rheostat 1.2kW Bank |
|
Brand |
Lab Exports |
|
Equipment type |
Adjustable resistive-load bank |
|
Rated loading capacity |
1.2 kW |
|
Load characteristic |
Resistive |
What’s Included in the Kit
One Loading Rheostat 1.2kW Bank
Integrated resistance-loading assembly
Load-adjustment control or selection switches
Electrical connection terminals
Connecting leads and operating instructions only when listed in the quotation
Applications and Uses
Applying an adjustable resistive load to compatible circuits
Studying current, voltage and power under changing load
Testing compatible motors and generators
Demonstrating resistive power dissipation
Comparing no-load and loaded operating conditions
Supporting electrical machines and circuit-training practicals
How to Use the Loading Rheostat 1.2kW Bank
Confirm the voltage, current, resistance and 1.2 kW ratings.
Set the control to the minimum-load or maximum-resistance position.
Isolate the electrical supply before making connections.
Connect the rheostat according to the approved experiment diagram.
Check terminal tightness, earthing and protective devices.
Energise the circuit under qualified supervision.
Adjust the load gradually while monitoring voltage, current and temperature.
Return the control to its starting position before switching off.
Allow the resistance elements to cool before handling.
Safety note: A rheostat converts electrical energy into heat. Do not touch the resistance elements during or immediately after operation, and never exceed the confirmed electrical rating.
Care & Maintenance
Inspect terminals, cables, insulation and earthing before use.
Keep ventilation areas clear and remove dust only when isolated.
Protect the unit from moisture, impact and unauthorised adjustment.
Allow complete cooling before cleaning, moving or storing the apparatus.
Why Choose Lab Exports
Lab Exports manufactures and exports scientific laboratory instruments, experiment setups, science kits, mathematics kits, didactic models and STEM equipment. Its electrical training range supports practical circuit analysis and machine-testing activities. Products are supplied for educational institutions, vocational laboratories and international procurement. Buyers should approve the final electrical and safety specifications before ordering.
Frequently Asked Questions
What is a Loading Rheostat 1.2kW Bank used for?
It is used to apply and vary a resistive load during electrical circuit, motor, generator and power-measurement experiments.
What does the 1.2kW rating mean?
It is the stated power-loading capacity under specified operating conditions. The permitted duty cycle must also be confirmed.
How does a loading rheostat control current?
Increasing or decreasing its resistance changes the current flowing through a compatible circuit according to the applied voltage.
Can it be used with AC and DC circuits?
The supported supply type is not confirmed. Verify AC or DC compatibility before connecting the apparatus.
Does the rheostat become hot?
Yes. Resistive loading produces heat, so ventilation, safe clearance and cooling time are required.
Can students operate the unit?
Students may use it only under direct supervision by qualified teaching or technical personnel.
Request the confirmed resistance, voltage, current and duty-cycle specifications for the Loading Rheostat 1.2kW Bank. Explore related Electrical and Electronics Equipment, compatible Lab Meters, the Ohm’s Law Kit with Built-in Power Supply and complete Physics Lab Equipment range.
Recommended Product Image ALT Text
Loading Rheostat 1.2kW Bank for adjustable resistive-load laboratory experiments
Variable resistance load bank with controls and electrical terminals
Laboratory rheostat bank for motor and generator loading experiments
Electrical resistive-load unit for engineering training laboratories
