Loading Inductor 1.2KVAR Bank Manufacturer,Supplier and Exporter in India

Loading Inductor 1.2KVAR Bank

Product Code : SCL-EAE-11308

The Loading Inductor 1.2 kVAR Bank has a stated reactive-load capacity of 1.2 kilovolt-amperes reactive. In an inductive AC circuit, current generally lags voltage because energy is temporarily stored in a magnetic field. The unit therefore supports practical demonstrations of alternating-current circuit behaviour.

The supplied product data does not identify operating voltage, frequency, phase configuration, load steps, enclosure material, winding construction, dimensions or terminal arrangement. These details must be confirmed against the final quotation and wiring documentation before ordering or connection. Buyers requiring a higher stated capacity can also review the Loading Inductor 2.4 kVAR.

Key Features

Stated 1.2 kVAR capacity: Provides a confirmed reactive-load rating of 1.2 kVAR.

Inductive AC loading: Introduces a lagging load into a compatible alternating-current circuit.

Phase-relation study: Helps learners observe current and voltage behaviour under inductive loading.

Reactive-power training: Supports practical work involving active, apparent and reactive power.

Electrical-machine use: Can support compatible alternator, generator and transformer experiments after rating verification.

Comparative learning: Enables comparison with resistive and capacitive loading.

Specification-led procurement: Requires verification of electrical ratings, duty cycle and protection before use.

Technical Specifications

Loading Inductor 1.2 kVAR Bank specifications

Specification

Detail

Product name

Loading Inductor 1.2 kVAR Bank

Brand

Lab Exports

Product category

Electrical and Electronics Laboratory Equipment / AC Load Bank

Load type

Inductive AC reactive load

Rated reactive capacity

1.2 kVAR

What's Included in the Kit

One Loading Inductor 1.2 kVAR Bank.

Cables, meters, manuals and accessories only when listed in the accepted quotation.

Applications and Uses

Demonstrating lagging current in AC circuits.

Studying active, reactive and apparent power.

Measuring or calculating lagging power factor.

Loading compatible alternators, generators, transformers and AC trainers.

Comparing the unit with a general inductive load apparatus.

Comparing inductive behaviour with a resistive load bank and compatible capacitive loading.

Supporting power-factor correction experiments with suitable equipment.

Teaching electrical machines and power systems.

How to Use the Loading Inductor 1.2 kVAR Bank

Confirm the source voltage, frequency, phase, current and protection requirements.

Place the unit on a dry, stable and adequately ventilated laboratory bench.

Isolate the electrical supply before making or changing connections.

Inspect earthing, terminals, cables, insulation and protective devices.

Set the load control to its minimum or disconnected position, where applicable.

Connect the bank according to the approved circuit diagram.

Energise the system under qualified supervision and apply the load gradually.

Monitor voltage, current, power factor, power and temperature.

Return to minimum load, isolate the supply and allow cooling before disconnection.

Safety note: Inductive circuits can generate switching transients. Never touch terminals or change connections while the circuit is energised. Do not exceed the confirmed ratings or permitted duty limits.

Care and Maintenance

Keep terminals, controls and ventilation areas clean and dry.

Inspect insulation, earthing and terminal tightness before each session.

Allow the apparatus to cool before cleaning, moving or storage.

Arrange periodic electrical and insulation checks by qualified personnel.

Why Choose Lab Exports

Lab Exports manufactures and exports scientific instruments, educational laboratory equipment, experiment setups, science kits, mathematics kits, didactic models and STEM products. Its equipment range serves schools, colleges, universities, engineering institutions and vocational laboratories. Buyers should approve the complete electrical specification and included accessories before production or dispatch.

Frequently Asked Questions

What is a Loading Inductor 1.2 kVAR Bank used for?

It applies an inductive reactive load to a compatible AC circuit for experiments involving current lag, reactive power, power factor and electrical-machine loading.

What does the 1.2 kVAR rating mean?

The 1.2 kVAR value is the stated reactive-power capacity of the bank. It is not equivalent to 1.2 kW of active power.

Does an inductive load cause current to lag voltage?

Yes. In a predominantly inductive AC load, current generally lags voltage. The exact phase displacement depends on the circuit impedance and operating conditions.

Is this loading inductor single-phase or three-phase?

The phase configuration has not been supplied. Confirm the required phase, voltage and frequency before ordering.

Can it be used with an alternator or transformer?

It can be used when all electrical and reactive-power ratings are compatible. A qualified person should verify the circuit before connection.

Can students use this loading inductor bank?

Yes, for supervised engineering and vocational laboratory work. Direct control by qualified teaching or technical personnel is required.

Request a quotation with confirmed voltage, frequency, phase and load configuration, or explore the complete electrical and electronics laboratory equipment range from Lab Exports.

```

   
Supply of Loading Inductor 1.2KVAR Bank from to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]